What a cyclic voltammogram is
In Lab 1 we held the current and watched the potential. Cyclic voltammetry does the opposite: it drives the potential of an electrode and records the current that flows. The potential is swept linearly in time from an initial value to a switching potential and back; the rate of the sweep, in mV/s or V/s, is the scan rate, and the plot of current against potential is the cyclic voltammogram.1,2 A sweep in one direction only is linear sweep voltammetry.2
Why bother? A voltammogram shows at a glance where a material is oxidized and reduced and whether the reaction comes back; by changing the scan rate it separates fast from slow processes, diffusion from surface reactions, and it can estimate how fast ions diffuse.2 That breadth is also the trap: the same review warns that interpretations of CV in battery research are often deficient or disputed, and that the technique should not be used without the basic electrochemistry behind it.2 This page builds that basis, starting from a dissolved molecule and ending with battery electrodes and electrolytes.
The measurement needs three electrodes. The working electrode is where the reaction of interest happens: an inert disc of glassy carbon, platinum or gold, polished before each run, or, in battery work, the composite electrode itself. The reference electrode fixes the potential scale; the counter electrode, an inert platinum wire larger than the working electrode, carries the current so that the reference does not have to.1 The solution holds the analyte in a large excess of supporting electrolyte, which carries the current and keeps the analyte from migrating in the field, so that it moves by diffusion alone; and dissolved oxygen, which gives peaks of its own, is removed by bubbling an inert gas through it first.1